Our new liquid temperature sensor features a short tip for use in a gauge port or hose fitting and not block flow. Standard GM coolant scaling means easy dropdown setup for most ECUs on the market however we do provide a scaling chart if needed.
Also features the standard 2-wire GM Packard connector. The mating connector is available as an add on when you order.
Fahrenheit | Ohms |
0 | 25,580 |
14 | 16,321 |
23 | 12,413 |
32 | 9,516 |
41 | 7,354 |
50 | 5,728 |
59 | 4,496 |
68 | 3,555 |
77 | 2,830 |
86 | 2,268 |
95 | 1,828 |
104 | 1,483 |
113 | 1,120 |
122 | 992 |
131 | 819 |
140 | 679 |
149 | 566 |
158 | 475 |
167 | 400 |
176 | 338 |
185 | 287 |
194 | 249 |
203 | 210 |
212 | 180 |
221 | 156 |
230 | 135 |
239 | 117 |
248 | 102 |
257 | 89 |
266 | 78 |
275 | 69 |
280 | 61 |
293 | 54 |
302 | 48 |
Part #: MADShortLiquidTemp